Aqua Broadcast Cobalt CH-1 Fully featured 1+1 Changeover Switch

Aqua Broadcast Cobalt CH-1 Fully featured 1+1 Changeover Switch

23.806 DKK

Model/Varenr.: AQ-Cobalt CH-1
Lagerstatus: Afsendes indenfor 7-14 arbejdsdage
Styk

Aqua Broadcast CH-1 Changeover switch

A versatile controller unit designed to monitor and manage redundant broadcast systems for FM radio transmission. This system ensures smooth transitions between transmitters, minimizing downtime in the event of a failure. It offers both automatic and manual operation modes with remote control or local management for maintenance and system testing. 

Built on the proven COBALT platform, the CH-1 gives you added confidence when using a secondary or backup transmitter. The unit features a built-in DPDT relay, offering more flexibility than standard SPDT relays and adding the possibility of testing the backup exciter on a dummy load without interrupting the main transmission. 

You can use the internal relay for exciters or low power transmitters but if you require to switch greater power transmitters you can easily integrate external RF switches from renowned brands like Spinner through the rear connectors.

A set of interlocks on the rear panel is also included, along with a +48VDC power input for added redundancy in critical scenarios.

To simplify system configuration, most settings can be adjusted via software. This includes input status, output controls and interlock polarities, fault detection methods (both digital and analogue), timers, and analogue thresholds. All are fully user-programmable in software for added convenience

Controls and monitoring are available through various methods, including web, SNMPv1, v2C, and v3, as well as email alerts and notifications.

The front panel includes the easy-to-use COBALT joystick and a clear OLED display. A set of LED indicators provides real-time status updates, with a clear diagram showing the current system operation.

Setup via the GUI is quick and intuitive. You can set up various time settings to allow for faster changeovers when needed and define the number of permissible automatic switches. On the local mode, full control from the control panel is given to the engineers during maintenance without external interference. By using the handy scheduled tests you will ensure the backup transmitter is always ready when it is most needed.   

Built for redundancy, designed for safety, and engineered for excellence, the Aqua Broadcast Changeover System keeps your broadcast on air, no matter what.

 

Features:

  • Linux O/S
  • RGB screen and LED synoptic
  • Built-in DPDT RF relay switch (latching), 100W max. 
  • Built in RF power measurement for internal RF relay inputs
  • Built in automatic failover logic with RF power detectors
  • Automatic and Manual switching modes
  • Dummy load connection for exciter testing
  • Dedicated interlocks outputs (relay) and interlock inputs (antenna systems and loads) 
  • +48VDC power input
  • Ethernet Control and SNMP

GENERAL

Input ACV @ 50/60Hz 100-240 (277 North America only)
Input DCV +48V
Power Connector IEC 13A filtered
Power consumption 1<70W @ max power
Dimensions WxDxH [inch] 19 x 15 x 1RU (1.75”)
Dimensions WxDxH [cm] 48.3 x 38 x 4.45
Weight 3.4 Kg / 7.5lb

RF INTERFACE

RF Input 2 x N-Type female (up to 100W)
RF Output 2 x N-Type female (up to 100W)

RF RELAY INTERFACE

Connector type D-Sub25 female
External Supply Voltage 24V DC @1.1A
SPINNER compatibility BN 512690C0002 (2kW)
Relay selection Internal DIP switches

EXCITER / TRANSMITTER INTERFACE

Connector type D-Sub15 female
External Supply Voltage 12V DC @0.75A
Digital Input 6x (optical isolated)
Digital Output 6x (optical isolated)
Analogue Input (optional)  2 x, 0-6V range
Analogue Output (optional) 2 x, 0-6V range

AMPLIFIER CONTROL INTERFACE

Connector type  D-Sub15 female
External Supply Voltage 12V DC @0.75A
Digital Input ≥6x (optical isolated)
Digital Output 6x (optical isolated)
Analogue Input (optional) 2x, 0-6V range

ANT/LOAD/GPIO INTERFACE

Connector type D-Sub25 female
External Supply Voltage 12V DC @0.75A
Digital Input 4x (optical isolated)
Digital Output 4x (optical isolated)
Analogue Input  2x, 0-6V range

INTERLOCK INTERFACE

Connector type Pluggable Terminal Block 8 Pos 3.81mm pitch
Output configuration 4x (Relay or Open collector optical isolated type) 
Relay configuration NC or NO
Output type selection and configuration Internal DIP switches

CONTROL INTERFACE

Connector type Pluggable Terminal Block 8 Pos 3.81mm pitch
Output configuration 4x (Relay or Open collector optical isolated type)
Relay configuration NC or NO
Output type selection and configuration Internal DIP switches

ENVIRONMENTAL

Altitude 15,000 ft / 4,420m AMSL
Temperature range 0 to +45ºC, working, -10 to +50ºC, storage
Humidity 95% @ 35ºC, non-condensing
Titel Type Størrelse Download
AQUA-BROADCAST-CH-1-Changeover-datasheet-221024.pdf PDF 502.29KB Download

Produktets tags

Der er ingen tags registreret.

Mine tags